High fracture resistance; verified compatible partial-coverage system
Named product lacks onlay indication or bonding conditions unsuitable
Resin-matrix CAD/CAM block
Repairability and resin-based design are useful
Wear/finish limitations or unsuitable block/adhesive system
Direct composite
Defect can be restored predictably without indirect preparation
Large structural compromise or access/isolation limits
Lithium disilicate onlay / overlay
Recommended starting point
A dependable aesthetic adhesive option when restoration thickness, remaining tissue and isolation support bonding.
When to change course
If the margin cannot be isolated, enamel is scarce, or approved thickness cannot be achieved, reassess restoration design before cutting extra tooth solely to accommodate ceramic.
Technical detail & laboratory prescription
Why this is useful
Etchable glass ceramic with established silane/resin-cement workflows; versatile anatomical control.
Technical / clinical detail
Different IPS e.max CAD indications have different minimums; the named current IPS e.max CAD IFU is the source of truth. The published Ivoclar document includes 1.0 mm minimally invasive adhesive designs alongside other thicker crown/partial-crown configurations. Avoid transferring one figure to all designs. Treat glass-ceramic with approved etch/silane protocol; do not apply that chemistry to zirconia.
Laboratory prescription
Tooth, cusp coverage, prep and opposing scan, static/dynamic occlusion, shade/stump shade, subgingival/deep margin location and proposed bonding strategy.
Consider early for a high-load posterior restoration where the patient accepts a visible metal surface.
When to change course
Reconsider for unacceptable appearance, metal sensitivity, lack of adequate margin/retention, or inability to provide sound cast dimensions.
Technical detail & laboratory prescription
Why this is useful
Appropriate cast alloy can permit conservative preparation and has an established clinical history.
Technical / clinical detail
Cast-metal design requirements vary with alloy, margin type and occlusion. Do not borrow ceramic shoulder/adhesive specifications for metal. Confirm casting alloy and whether conventional or adhesive cementation is planned.
Laboratory prescription
Exact alloy where known; margin design, tooth/surfaces, opposing and bite, desired contact and occlusion.
A reasonable material choice when fracture resistance is valuable and the particular zirconia system explicitly permits inlays/onlays.
When to change course
If the system is not approved for the indication, or a reliable adhesive workflow is unavailable.
Technical detail & laboratory prescription
Why this is useful
High-strength ceramic; selected systems offer partial-coverage indications.
Technical / clinical detail
Verified example, IPS e.max Zirconia (2026 guide): posterior inlay/onlay minimum wall thickness 0.5 mm; the same named guide lists adhesive cementation for inlays/onlays. Also reports minimum inlay depth 0.5 mm, fissure isthmus 1.0 mm, and at least 1.0 mm space in cusp-capping areas. These are different concepts: do not confuse wall thickness with preparation depth and functional cusp clearance. Zirconia is not HF etched; follow approved surface cleaning, conditioning and MDP protocol.
Laboratory prescription
Exact commercial material and approved indication, scan, opposing, bite, space, adhesive plan.
Use where the properties and repairability of a resin-matrix indirect restoration make sense, with a reliable adhesive workflow.
When to change course
Product not indicated for the desired restoration, allergy to methacrylate constituents, inadequate reduction or unsuitable cementation.
Technical detail & laboratory prescription
Why this is useful
CAD/CAM resin-matrix options are not the same material or bonding category as silica glass ceramics.
Technical / clinical detail
GC CERASMART 270 IFU: for onlays minimum 1.5 mm in cusp and pit/fissure zones and 1.0 mm at margins; rounded internal angles, deep chamfer/rounded shoulder, avoid direct marginal occlusal contacts. For adhesive cementation, manufacturer describes 25–50 μm alumina at 1.5 bar, clean/dry, silane-containing primer, adhesive resin cement. Check current country-specific IFU.
Laboratory prescription
Named CAD/CAM block, restoration surfaces, margin/clearance, scan and bite, shade, intended resin-cement system.
Dark substrate, required opacity, thickness, bonding
Short / poorly retentive crown
Reconsider resistance form and core/restorability
A stronger ceramic cannot remedy a fundamentally weak prep
Metal accepted and conservative posterior
Cast metal
Alloy, space, appearance and consent
Monolithic zirconia crown
Recommended starting point
Strong routine option for a well-prepared posterior crown under substantial loading.
When to change course
Anterior shade match/opacity, inadequate retention or preparation geometry, too-thin specific design.
Technical detail & laboratory prescription
Why this is useful
Avoids a conventional veneering porcelain layer and has high fracture resistance.
Technical / clinical detail
3Y, 4Y and 5Y categories do not have identical mechanical/optical properties; select grade and brand for the indication. Verified IPS e.max Zirconia 2026 example: anterior crown 0.6 mm and posterior crown 0.7 mm minimum restoration wall thickness. For conventional/self-adhesive cementation the same named guide describes retentive surfaces including minimum stump height 4 mm. After occlusal adjustment polish zirconia rather than leaving roughened contacts.
Laboratory prescription
Tooth, prep scan, opposing/bite, desired opacity/shade, available clearance, restoration grade and proposed cementation.
Aesthetic single crown when space, shade and approved seating method align.
When to change course
Marked discolouration requiring masking, high-load thin design, unsuitable retention or inadequate isolation for an adhesion-dependent configuration.
Technical detail & laboratory prescription
Why this is useful
Established aesthetic and glass-ceramic adhesive options, with different translucency/opacity versions.
Technical / clinical detail
Some IPS e.max CAD full crowns may be conventionally, self-adhesively or adhesively cemented depending on the exact indication. The manufacturer also describes a distinct 1-mm minimally invasive adhesive full crown with restrictions; it is not a universal recommendation for all teeth or patients. Verify the selected IPS e.max CAD/Press design and current eIFU.
Laboratory prescription
Stump and desired shade, shade-tab photographs, type/extent of coverage, margin, scans/bite, proposed luting method.
Feldspathic: high aesthetic control in enamel-dominant, appropriately supported veneers; technique-sensitive. Lithium disilicate: aesthetic ceramic option when a suitable thickness and optical/adhesive strategy are planned. Composite: repairable and more directly adjustable but maintenance/staining depend on product and behaviour.
Case changer: dark stump + very thin translucent ceramic may not mask reliably. Shade-tab photograph, calibrated stump shade, enamel distribution, required masking and cement shade trial should be considered before promising the result. Do not guarantee final colour based on ceramic brand alone.
Approved tooth-supported span with adequate connector geometry
System grade, number/location of pontics, connector height/area
PFM bridge
Selected longer spans, established metal-ceramic framework
Metal visibility, veneering chipping, available design space
Lithium disilicate bridge
Specifically approved short anterior/premolar configurations
Do not extend an approved span to arbitrary posterior bridges
Lab question: “Can you make a four-unit bridge here?” Send prep and opposing scans, actual connector height, pontic positions, available interocclusal space, chosen material/system and occlusal plan. A yes/no based on unit count is misleading.
Technical / clinical detail
Verified connector example: IPS e.max Zirconia 2026: posterior 3-unit connector 12 mm²; posterior bridge with two connected pontics 15 mm² (20 mm² between pontics), with additional wall/zone rules. This is not a general zirconia connector chart. The manufacturer emphasises connector height more than width and limits posterior bridge constructions to two consecutive pontics. [S4, S5]
Post: retains a core; does not make a structurally compromised root stronger. Ferrule, remaining tissue, periodontal/endodontic prognosis and planned definitive restoration drive the choice. Custom cast: useful in selected canal forms. Fibre: alternate restorative strategy where indicated. Provisional: mill/print only from validated temporary materials for intended duration; record occlusion, emergence, desired diagnostic changes. Printed definitive crown: material/indication approval, processing and evidence must be evaluated separately from PMMA temporaries.
Bulk and support control if prolonged definitive use
Flexible polyamide
Selected aesthetic short bounded saddles
Distal extension, reline/additions, insufficient rigid support
Acetal components
Aesthetic clasp on an otherwise properly designed framework
Bulky clasp dimensions and retention behaviour
Titanium / PEEK / PEKK
Specific weight/design goals or material constraints
Not direct equivalents to CoCr stiffness/repair/evidence
Distal extension: start with support, direct/indirect retention, abutment health and survey, not the requested material. A flexible denture is not automatically an equivalent replacement for a rigid support framework. BSSPD published peer-reviewed partial denture design guidance in 2026. [S7]
Laboratory prescription & records
Required lab records: Kennedy classification and saddle locations; tooth prognosis and expected extractions; survey/rest seats; path of insertion, clasp display preferences, occlusal records and impression method. Encourage design approval before manufacture for complex RPDs.
Complete dentures / digital dentures — practical selection
Design
Useful first option
Do not expect
Heat-cured PMMA
Conventional full denture, repair/reline flexibility
Material alone to fix poor borders/occlusion
High-impact PMMA
Impact fracture risk, e.g. repeated drops
To stop repeated flexural failure from poor fit
Milled digital PMMA
Stored design/remake workflow
Good fit despite inadequate clinical records
3D-printed denture base
Validated final-denture system and process
Any temporary-print resin to be a permanent base
Soft liner / tissue conditioner
Selected cushioning or short-term tissue management
Long-term cure for unstable denture
Repeated fracture pathway: locate fracture line; distinguish impact from flexural fatigue; check opposing natural/implant-supported arch, midline thickness, anterior notch, base extension/fit and past repair design. Choose repair/reline/rebase/remake according to the underlying problem, rather than automatically using stronger acrylic.
Laboratory prescription & records
Lab records: existing denture (where feasible), fracture photographs and date history, occlusal relationship and opposing dentition, planned base/teeth change, facial/aesthetic records and desired vertical dimension.
Conventional acrylic teeth: easily adjusted and bonded to PMMA, with wear behaviour depending on product. Highly crosslinked/composite denture teeth: alternative wear/aesthetic profiles; check specific chemistry and wear against opposing restorations. Porcelain teeth: uncommon, may increase opposing wear/weight and present retention challenges. Soft silicone liners need review for debonding/biofilm; tissue conditioners are short-term materials.
Clinical direction: prefer screw retention where feasible for retrievability and avoidance of residual intraoral cement. Cement retention remains reasonable where anatomy and accessible margins justify it. Neither approach eliminates biologic or mechanical complications; ITI consensus supports individualised selection. [S8, S9]
1. Obtain historical implant placement card and operative records. 2. Record manufacturer, model, connection and platform; an implant box photo is supportive but not always conclusive. 3. Obtain appropriate imaging/clinical information if uncertainty persists. 4. Confirm the exact scan body and restorative library against the manufacturer or validated compatible supplier. 5. Only then choose Ti-base, abutment and screw. Do not infer cross-system fit from visual similarity.
Laboratory prescription & records
Lab referral dataset: implant system + model + platform/connection; implant- versus abutment-level scan; exact scan body part ID; tissue/cuff height; available vertical restorative space; access-axis constraints; bite/opposing scan; preferred restoration; approved component policy.
Implant splinting and retention in planned prosthesis
Bar hygiene, space, clip and component care
A fixed restoration is not inherently superior. Check hygiene access, dexterity, speech, smile line, prosthetic space, opposing arch and the patient’s realistic maintenance capacity. The 2026 global consensus on edentulous maxillary rehabilitation supports planning around patient- and prosthesis-specific factors. [S9]
Partial-coverage appliance only with supervised short-term plan
Unwanted tooth movement if unsupervised
Do not market a protection splint as a proven treatment for chronic painful TMD. The 2023 BMJ guideline conditionally recommends against reversible occlusal splints for chronic TMD pain compared with alternative management. Tooth-wear protection is a separate clinical objective. [S10]
Clear vacuum-formed: discreet and replicable from saved final scans; consider wear, cracking and patient adherence. Hawley: wire-acrylic design with adjustability in selected settings, but more visible. Fixed bonded: reduces reliance on removable compliance, but needs hygiene and review for partial debonding or unintended active-wire movements. The British Dental Journal review notes no universal best retention protocol and supports patient-specific regimens. [S11]
Sports mouthguards: finished thickness, not starting sheet
A custom EVA mouthguard should provide retention, coverage and an appropriate final thickness.
Technical / clinical detail
Academy for Sports Dentistry 2024 position statement cites at least 3 mm occlusal/labial thickness; the American College of Prosthodontists describes about 4 mm for most contact sports and 5–6 mm for higher-risk activities. The 2025 European position statement discusses 3–4 mm labial thickness over central incisors and 1.5–2 mm incisal protection, reflecting design-specific requirements. Do not treat these organisations’ figures as a single interchangeable specification. [S12–S14]
Laboratory prescription & records
For orthodontic patients and growing dentitions, plan relief and more frequent replacement. Prescription: sport and level, age, eruption/orthodontic state, chosen arch, scans and bite, special design/colour, requested final thickness.
Do not assume snoring is uncomplicated primary snoring: consider OSA assessment. NICE NG202 recommends considering customised or semi-customised MAD in selected adults with mild symptomatic OSAHS who decline or cannot tolerate CPAP and have appropriate dental/periodontal health; guidance also considers other severity groups. Dental review includes periodontal support, TMD/occlusal symptoms, sufficient anchorage and possible long-term bite changes. [S15]
Laboratory prescription & records
Prescription: diagnosis and sleep-service collaboration, device type and titration plan, protrusion registration, maximum protrusive range, accurate two-arch records and bite, medical/dental monitoring arrangements.
Specify arch, coverage, scalloped versus non-scalloped margin preferences, reservoir approach only if the chosen bleaching system requires it, and material thickness according to that system. Tray design should not be promoted as independent evidence of efficacy or safety.
Cementation — restore confidence without oversimplifying
Restoration
First useful protocol distinction
Critical warning
Lithium disilicate
Approved glass-ceramic etching, silane and resin bonding for adhesive indications
Onlay / veneer protocol differs from some full crowns
Zirconia
Approved surface conditioning + MDP-based chemistry when adhesive bonding needed
HF etching is not equivalent to glass ceramic
Feldspathic / leucite
Etchable glass ceramic and adhesive resin cement
Not a conventional-luting substitute
Metal/PFM
Conventional cement often possible with retentive prep; primers when bonding
Alloy, contamination and design determine chemistry
Resin-matrix CAD/CAM
Product-specific mechanical treatment, primer and resin cement
Not all hybrid blocks are etched or conditioned like e.max
Temporary
Suitable provisional cement, often eugenol-free where future bonding matters
Temporary duration and product compatibility
After try-in: contamination can undermine bonding. Follow ceramic-specific cleaning and conditioning sequence; choose cement type from material, preparation retention, restoration design, isolation and current product IFU. Do not use an all-purpose 15-second flowchart for every product.
Yes when adequate bonded design and isolation are achievable. If margins cannot be isolated, evaluate margin exposure/elevation or change the restorative strategy rather than relying on stronger cement.
What enables the lab to answer
Photographs of margin, prep/opposing scans and proposed isolation/coverage.
Not safely from unit count alone. Assess actual connector height/area, pontic distribution, system-approved configurations, abutment support and loads.
What enables the lab to answer
Exact material system, complete prep and bite, connector space, pontic map.
Do not conflate protecting restorations with chronic painful TMD management. Use targeted assessment and evidence-based management; consider appliance only for an appropriate separate indication.
What enables the lab to answer
Occlusal and wear-risk prescription when tooth protection is the purpose.
Can I avoid a cement-retained anterior implant crown?
Practical direction
Evaluate manufacturer-supported angulated screw access and compatible Ti-base/abutment before defaulting to cement solely because the straight access is labial.
What enables the lab to answer
Exact implant platform, tissue, access axis and aesthetic scans.
Evidence-checked clinical and laboratory decision handbook | Research-expanded edition | 2 November 2026
This is a research-supported editorial master, not an independently peer-reviewed clinical guideline. It expands the uploaded 12-page Enhanced Clinical Edition and incorporates manufacturer specifications and professional guidance. Named figures apply only to the specific restoration, material and publication cited.
Compare material choice with actual preparation, connectors, space and retention
How do I seat it?
Section 5 surface treatment and cementation
What does the lab need?
Each entry includes a minimal prescription checklist
What has gone wrong?
Section 6 problem-solving / plan-change pathways
Editorial principle: a recommendation should be confident for its defined indication. Do not substitute a generic product class for named manufacturer clearance, connection or cementation requirements.
Records & prescription
What does the laboratory need?
Open the relevant topic’s laboratory prescription or records checklist.
Source classification: named product measurements are sourced from linked manufacturer material. Professional recommendations are sourced from organisations and clinical guidance listed above. Other clinical explanatory text is an editorial synthesis from the uploaded VEXA master and general restorative principles; it is not independently validated case-specific guidance.
Content coverage and publication control
Information architecture: six professional groups (Fixed, Removable, Implants, Appliances, Cementation, Clinical Questions). Users should find a restoration first, see three to five actionable options, then expand exactly the technical material they need. One authoritative entry per material; use internal links rather than duplicate paragraphs.
Not established here: a complete model-by-model implant compatibility catalogue; all proprietary zirconia grades and bridge specifications; all approved 3D-printed definitive resin systems; validated patient-specific case-planning recommendations. These require maintained data and expert oversight—not guessed specifications.
Before any public claim of clinical approval: independent restorative clinician review, GDC-registered technician review of fabrication/compatibility, date/version control, working direct IFU references for every named numerical protocol, and review of safety-critical recommendations. This master is not a clinical certification.
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional
Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes.The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.