VEXA Dental Lab

VEXA / For dental professionals

VEXA Clinical Reference

Built for dentists who want a clear answer first, followed by the detail that actually changes a restoration.

Research-expanded edition · 2 November 2026 Independent clinical sign-off required

6 clinical categories · 10 comparisons · 8 practical questions

Start with the clinical task

Choose a category. Get an answer. Open the detail you need.

A–Z material & clinical topic index
Fixed restorations

Onlay / overlay / inlay: first-pass options

Onlay / overlay / inlay: first-pass options
MaterialGood first option whenWhat overturns it
Lithium disilicate (IPS e.max CAD/Press)Bondable aesthetic partial coverage; enamel and isolation favourableDeep unisolatable margins, insufficient thickness, unsupported geometry
Cast goldPosterior conservation and long service; metal acceptedAesthetic demands, alloy sensitivity, preparation problems
Approved zirconia onlayHigh fracture resistance; verified compatible partial-coverage systemNamed product lacks onlay indication or bonding conditions unsuitable
Resin-matrix CAD/CAM blockRepairability and resin-based design are usefulWear/finish limitations or unsuitable block/adhesive system
Direct compositeDefect can be restored predictably without indirect preparationLarge structural compromise or access/isolation limits

Lithium disilicate onlay / overlay

Recommended starting point

A dependable aesthetic adhesive option when restoration thickness, remaining tissue and isolation support bonding.

When to change course

If the margin cannot be isolated, enamel is scarce, or approved thickness cannot be achieved, reassess restoration design before cutting extra tooth solely to accommodate ceramic.

Technical detail & laboratory prescription

Why this is useful

Etchable glass ceramic with established silane/resin-cement workflows; versatile anatomical control.

Technical / clinical detail

Different IPS e.max CAD indications have different minimums; the named current IPS e.max CAD IFU is the source of truth. The published Ivoclar document includes 1.0 mm minimally invasive adhesive designs alongside other thicker crown/partial-crown configurations. Avoid transferring one figure to all designs. Treat glass-ceramic with approved etch/silane protocol; do not apply that chemistry to zirconia.

Laboratory prescription

Tooth, cusp coverage, prep and opposing scan, static/dynamic occlusion, shade/stump shade, subgingival/deep margin location and proposed bonding strategy.

Evidence: [S1, S2]
Link to this material

Cast gold onlay

Recommended starting point

Consider early for a high-load posterior restoration where the patient accepts a visible metal surface.

When to change course

Reconsider for unacceptable appearance, metal sensitivity, lack of adequate margin/retention, or inability to provide sound cast dimensions.

Technical detail & laboratory prescription

Why this is useful

Appropriate cast alloy can permit conservative preparation and has an established clinical history.

Technical / clinical detail

Cast-metal design requirements vary with alloy, margin type and occlusion. Do not borrow ceramic shoulder/adhesive specifications for metal. Confirm casting alloy and whether conventional or adhesive cementation is planned.

Laboratory prescription

Exact alloy where known; margin design, tooth/surfaces, opposing and bite, desired contact and occlusion.

Evidence: [S3]
Link to this material

Zirconia onlay — only a named approved system

Recommended starting point

A reasonable material choice when fracture resistance is valuable and the particular zirconia system explicitly permits inlays/onlays.

When to change course

If the system is not approved for the indication, or a reliable adhesive workflow is unavailable.

Technical detail & laboratory prescription

Why this is useful

High-strength ceramic; selected systems offer partial-coverage indications.

Technical / clinical detail

Verified example, IPS e.max Zirconia (2026 guide): posterior inlay/onlay minimum wall thickness 0.5 mm; the same named guide lists adhesive cementation for inlays/onlays. Also reports minimum inlay depth 0.5 mm, fissure isthmus 1.0 mm, and at least 1.0 mm space in cusp-capping areas. These are different concepts: do not confuse wall thickness with preparation depth and functional cusp clearance. Zirconia is not HF etched; follow approved surface cleaning, conditioning and MDP protocol.

Laboratory prescription

Exact commercial material and approved indication, scan, opposing, bite, space, adhesive plan.

Evidence: [S4, S5]
Link to this material

Resin-matrix CAD/CAM onlay (GC CERASMART 270 example)

Recommended starting point

Use where the properties and repairability of a resin-matrix indirect restoration make sense, with a reliable adhesive workflow.

When to change course

Product not indicated for the desired restoration, allergy to methacrylate constituents, inadequate reduction or unsuitable cementation.

Technical detail & laboratory prescription

Why this is useful

CAD/CAM resin-matrix options are not the same material or bonding category as silica glass ceramics.

Technical / clinical detail

GC CERASMART 270 IFU: for onlays minimum 1.5 mm in cusp and pit/fissure zones and 1.0 mm at margins; rounded internal angles, deep chamfer/rounded shoulder, avoid direct marginal occlusal contacts. For adhesive cementation, manufacturer describes 25–50 μm alumina at 1.5 bar, clean/dry, silane-containing primer, adhesive resin cement. Check current country-specific IFU.

Laboratory prescription

Named CAD/CAM block, restoration surfaces, margin/clearance, scan and bite, shade, intended resin-cement system.

Evidence: [S6]
Link to this material
Link to this topic
Fixed restorations

Full crowns — quick choice

Full crowns — quick choice
SituationCommon first directionImportant qualifier
Posterior heavy loadingMonolithic zirconiaGrade, appropriate preparation, polished contacts
Aesthetic toothLithium disilicate or aesthetic zirconiaDark substrate, required opacity, thickness, bonding
Short / poorly retentive crownReconsider resistance form and core/restorabilityA stronger ceramic cannot remedy a fundamentally weak prep
Metal accepted and conservative posteriorCast metalAlloy, space, appearance and consent

Monolithic zirconia crown

Recommended starting point

Strong routine option for a well-prepared posterior crown under substantial loading.

When to change course

Anterior shade match/opacity, inadequate retention or preparation geometry, too-thin specific design.

Technical detail & laboratory prescription

Why this is useful

Avoids a conventional veneering porcelain layer and has high fracture resistance.

Technical / clinical detail

3Y, 4Y and 5Y categories do not have identical mechanical/optical properties; select grade and brand for the indication. Verified IPS e.max Zirconia 2026 example: anterior crown 0.6 mm and posterior crown 0.7 mm minimum restoration wall thickness. For conventional/self-adhesive cementation the same named guide describes retentive surfaces including minimum stump height 4 mm. After occlusal adjustment polish zirconia rather than leaving roughened contacts.

Laboratory prescription

Tooth, prep scan, opposing/bite, desired opacity/shade, available clearance, restoration grade and proposed cementation.

Evidence: [S4, S5]
Link to this material

Lithium disilicate full crown

Recommended starting point

Aesthetic single crown when space, shade and approved seating method align.

When to change course

Marked discolouration requiring masking, high-load thin design, unsuitable retention or inadequate isolation for an adhesion-dependent configuration.

Technical detail & laboratory prescription

Why this is useful

Established aesthetic and glass-ceramic adhesive options, with different translucency/opacity versions.

Technical / clinical detail

Some IPS e.max CAD full crowns may be conventionally, self-adhesively or adhesively cemented depending on the exact indication. The manufacturer also describes a distinct 1-mm minimally invasive adhesive full crown with restrictions; it is not a universal recommendation for all teeth or patients. Verify the selected IPS e.max CAD/Press design and current eIFU.

Laboratory prescription

Stump and desired shade, shade-tab photographs, type/extent of coverage, margin, scans/bite, proposed luting method.

Evidence: [S1, S2]
Link to this material
Link to this topic
Fixed restorations

Veneers — where the decision genuinely changes

Feldspathic: high aesthetic control in enamel-dominant, appropriately supported veneers; technique-sensitive. Lithium disilicate: aesthetic ceramic option when a suitable thickness and optical/adhesive strategy are planned. Composite: repairable and more directly adjustable but maintenance/staining depend on product and behaviour.

Case changer: dark stump + very thin translucent ceramic may not mask reliably. Shade-tab photograph, calibrated stump shade, enamel distribution, required masking and cement shade trial should be considered before promising the result. Do not guarantee final colour based on ceramic brand alone.

Link to this topic
Fixed restorations

Bridges — decide pontics, connectors and support before material

Bridges — decide pontics, connectors and support before material
DesignBest useTechnical stop point
Single-retainer resin-bonded cantileverConservative single-tooth replacement with suitable enamel abutmentOcclusion, retainer coverage/bonding, abutment prognosis
Monolithic zirconia fixed bridgeApproved tooth-supported span with adequate connector geometrySystem grade, number/location of pontics, connector height/area
PFM bridgeSelected longer spans, established metal-ceramic frameworkMetal visibility, veneering chipping, available design space
Lithium disilicate bridgeSpecifically approved short anterior/premolar configurationsDo not extend an approved span to arbitrary posterior bridges

Lab question: “Can you make a four-unit bridge here?” Send prep and opposing scans, actual connector height, pontic positions, available interocclusal space, chosen material/system and occlusal plan. A yes/no based on unit count is misleading.

Technical / clinical detail

Verified connector example: IPS e.max Zirconia 2026: posterior 3-unit connector 12 mm²; posterior bridge with two connected pontics 15 mm² (20 mm² between pontics), with additional wall/zone rules. This is not a general zirconia connector chart. The manufacturer emphasises connector height more than width and limits posterior bridge constructions to two consecutive pontics. [S4, S5]

Link to this topic
Fixed restorations

Posts, cores and provisionals

Post: retains a core; does not make a structurally compromised root stronger. Ferrule, remaining tissue, periodontal/endodontic prognosis and planned definitive restoration drive the choice. Custom cast: useful in selected canal forms. Fibre: alternate restorative strategy where indicated. Provisional: mill/print only from validated temporary materials for intended duration; record occlusion, emergence, desired diagnostic changes. Printed definitive crown: material/indication approval, processing and evidence must be evaluated separately from PMMA temporaries.

Link to this topic
Removable prosthodontics

Partial dentures — support first, polymer second

Partial dentures — support first, polymer second
OptionReason to chooseDesign limit
Cobalt-chrome (CoCr)Definitive surveyed RPD with rests and rigid control of loadPoor abutment prognosis; imminent extractions; allergy
Acrylic PMMAImmediate/transitional; easy addition/reline/repairBulk and support control if prolonged definitive use
Flexible polyamideSelected aesthetic short bounded saddlesDistal extension, reline/additions, insufficient rigid support
Acetal componentsAesthetic clasp on an otherwise properly designed frameworkBulky clasp dimensions and retention behaviour
Titanium / PEEK / PEKKSpecific weight/design goals or material constraintsNot direct equivalents to CoCr stiffness/repair/evidence

Distal extension: start with support, direct/indirect retention, abutment health and survey, not the requested material. A flexible denture is not automatically an equivalent replacement for a rigid support framework. BSSPD published peer-reviewed partial denture design guidance in 2026. [S7]

Laboratory prescription & records

Required lab records: Kennedy classification and saddle locations; tooth prognosis and expected extractions; survey/rest seats; path of insertion, clasp display preferences, occlusal records and impression method. Encourage design approval before manufacture for complex RPDs.

Link to this topic
Removable prosthodontics

Complete dentures / digital dentures — practical selection

Complete dentures / digital dentures — practical selection
DesignUseful first optionDo not expect
Heat-cured PMMAConventional full denture, repair/reline flexibilityMaterial alone to fix poor borders/occlusion
High-impact PMMAImpact fracture risk, e.g. repeated dropsTo stop repeated flexural failure from poor fit
Milled digital PMMAStored design/remake workflowGood fit despite inadequate clinical records
3D-printed denture baseValidated final-denture system and processAny temporary-print resin to be a permanent base
Soft liner / tissue conditionerSelected cushioning or short-term tissue managementLong-term cure for unstable denture

Repeated fracture pathway: locate fracture line; distinguish impact from flexural fatigue; check opposing natural/implant-supported arch, midline thickness, anterior notch, base extension/fit and past repair design. Choose repair/reline/rebase/remake according to the underlying problem, rather than automatically using stronger acrylic.

Laboratory prescription & records

Lab records: existing denture (where feasible), fracture photographs and date history, occlusal relationship and opposing dentition, planned base/teeth change, facial/aesthetic records and desired vertical dimension.

Link to this topic
Removable prosthodontics

Denture teeth and liners

Conventional acrylic teeth: easily adjusted and bonded to PMMA, with wear behaviour depending on product. Highly crosslinked/composite denture teeth: alternative wear/aesthetic profiles; check specific chemistry and wear against opposing restorations. Porcelain teeth: uncommon, may increase opposing wear/weight and present retention challenges. Soft silicone liners need review for debonding/biofilm; tissue conditioners are short-term materials.

Link to this topic
Implant prosthodontics

Single crowns: retention pathway

Single crowns: retention pathway
OptionStrong default whenIssue to resolve
Screw-retainedAccess channel and approved components allow acceptable anatomyLabial/incisal access, angulation and interface
Angulated screw-channelManufacturer-approved compatible channel can improve accessSystem-specific screws/drivers and maximum angulation
Cement-retained on abutmentScrew access unsuitable and margin can be exposed/cleanedExcess cement, reduced retrieval, margin visibility

Clinical direction: prefer screw retention where feasible for retrievability and avoidance of residual intraoral cement. Cement retention remains reasonable where anatomy and accessible margins justify it. Neither approach eliminates biologic or mechanical complications; ITI consensus supports individualised selection. [S8, S9]

Link to this topic
Implant prosthodontics

Abutments and restorative parts: not interchangeable

Abutments and restorative parts: not interchangeable
PartClinical/lab roleConfirm before ordering
Stock titanium abutmentPrefabricated supportExact connection, cuff height, margins, angulation
Custom titanium CAD/CAMCustom emergence and margin positionProsthetic space, milling interface, tissue level
Ti-baseBondable titanium interface to compatible restorationBase height, connection and bonded material approval
Zirconia on Ti-baseCeramic aesthetics with titanium implant interfaceCeramic dimension, bonding and tissue thickness
One-piece zirconia abutmentCeramic-to-implant interface in approved systemsConnection fracture/approval
Multi-unit abutmentRestorative level for bridges/full archAngulation, cuff, screw system, compatibility
Scan bodyTransfers implant position digitallyImplant-level vs abutment-level, library and correct body
Link to this topic
Implant prosthodontics

Unidentified implant: safe identification workflow

1. Obtain historical implant placement card and operative records. 2. Record manufacturer, model, connection and platform; an implant box photo is supportive but not always conclusive. 3. Obtain appropriate imaging/clinical information if uncertainty persists. 4. Confirm the exact scan body and restorative library against the manufacturer or validated compatible supplier. 5. Only then choose Ti-base, abutment and screw. Do not infer cross-system fit from visual similarity.

Laboratory prescription & records

Lab referral dataset: implant system + model + platform/connection; implant- versus abutment-level scan; exact scan body part ID; tissue/cuff height; available vertical restorative space; access-axis constraints; bite/opposing scan; preferred restoration; approved component policy.

Link to this topic
Implant prosthodontics

Full arch: fixed versus removable

Full arch: fixed versus removable
ChoiceWhy selectLikely maintenance
Titanium framework with acrylic/compositeFramework rigidity and replaceable teeth/veneeringWear, fracture, tooth/veneering repairs
Monolithic zirconia fixed archSuitable strong full-arch design, wear/stain prioritiesDifficult repair after major structural fracture
Stud attachment overdentureRemovable hygiene and replaceable insertsInsert wear, attachment maintenance
Bar overdentureImplant splinting and retention in planned prosthesisBar hygiene, space, clip and component care

A fixed restoration is not inherently superior. Check hygiene access, dexterity, speech, smile line, prosthetic space, opposing arch and the patient’s realistic maintenance capacity. The 2026 global consensus on edentulous maxillary rehabilitation supports planning around patient- and prosthesis-specific factors. [S9]

Link to this topic
Appliances

Splints: choose the actual purpose

Splints: choose the actual purpose
RequestUsual design directionCheck
Tooth / restoration protection with controlled contactsHard full-coverage stabilisationFit, occlusal scheme, adjustments, recall
Cushioned fitting surface + harder occlusal surfaceDual-laminateBulk and possible delamination
Interim resilient protectionSoft EVAWear/perforation and adjustment limits
Diagnostic deprogrammingPartial-coverage appliance only with supervised short-term planUnwanted tooth movement if unsupervised

Do not market a protection splint as a proven treatment for chronic painful TMD. The 2023 BMJ guideline conditionally recommends against reversible occlusal splints for chronic TMD pain compared with alternative management. Tooth-wear protection is a separate clinical objective. [S10]

Link to this topic
Appliances

Retainers: a clinically distinct decision

Clear vacuum-formed: discreet and replicable from saved final scans; consider wear, cracking and patient adherence. Hawley: wire-acrylic design with adjustability in selected settings, but more visible. Fixed bonded: reduces reliance on removable compliance, but needs hygiene and review for partial debonding or unintended active-wire movements. The British Dental Journal review notes no universal best retention protocol and supports patient-specific regimens. [S11]

Link to this topic
Appliances

Sports mouthguards: finished thickness, not starting sheet

A custom EVA mouthguard should provide retention, coverage and an appropriate final thickness.

Technical / clinical detail

Academy for Sports Dentistry 2024 position statement cites at least 3 mm occlusal/labial thickness; the American College of Prosthodontists describes about 4 mm for most contact sports and 5–6 mm for higher-risk activities. The 2025 European position statement discusses 3–4 mm labial thickness over central incisors and 1.5–2 mm incisal protection, reflecting design-specific requirements. Do not treat these organisations’ figures as a single interchangeable specification. [S12–S14]

Laboratory prescription & records

For orthodontic patients and growing dentitions, plan relief and more frequent replacement. Prescription: sport and level, age, eruption/orthodontic state, chosen arch, scans and bite, special design/colour, requested final thickness.

Link to this topic
Appliances

Mandibular advancement devices (MAD)

Do not assume snoring is uncomplicated primary snoring: consider OSA assessment. NICE NG202 recommends considering customised or semi-customised MAD in selected adults with mild symptomatic OSAHS who decline or cannot tolerate CPAP and have appropriate dental/periodontal health; guidance also considers other severity groups. Dental review includes periodontal support, TMD/occlusal symptoms, sufficient anchorage and possible long-term bite changes. [S15]

Laboratory prescription & records

Prescription: diagnosis and sleep-service collaboration, device type and titration plan, protrusion registration, maximum protrusive range, accurate two-arch records and bite, medical/dental monitoring arrangements.

Link to this topic
Appliances

Bleaching trays

Specify arch, coverage, scalloped versus non-scalloped margin preferences, reservoir approach only if the chosen bleaching system requires it, and material thickness according to that system. Tray design should not be promoted as independent evidence of efficacy or safety.

Link to this topic
Cementation

Cementation — restore confidence without oversimplifying

Cementation — restore confidence without oversimplifying
RestorationFirst useful protocol distinctionCritical warning
Lithium disilicateApproved glass-ceramic etching, silane and resin bonding for adhesive indicationsOnlay / veneer protocol differs from some full crowns
ZirconiaApproved surface conditioning + MDP-based chemistry when adhesive bonding neededHF etching is not equivalent to glass ceramic
Feldspathic / leuciteEtchable glass ceramic and adhesive resin cementNot a conventional-luting substitute
Metal/PFMConventional cement often possible with retentive prep; primers when bondingAlloy, contamination and design determine chemistry
Resin-matrix CAD/CAMProduct-specific mechanical treatment, primer and resin cementNot all hybrid blocks are etched or conditioned like e.max
TemporarySuitable provisional cement, often eugenol-free where future bonding mattersTemporary duration and product compatibility

After try-in: contamination can undermine bonding. Follow ceramic-specific cleaning and conditioning sequence; choose cement type from material, preparation retention, restoration design, isolation and current product IFU. Do not use an all-purpose 15-second flowchart for every product.

Link to this topic
Cementation

Quick protocol checks before seating

  • Confirm exact restoration substrate and branded material (not just “ceramic”).
  • Confirm whether the restoration is mechanically retentive or requires adhesive support.
  • Determine whether surface treatment happened in the lab and what must be repeated after try-in.
  • Check tooth-side isolation, enamel/dentine/substrate and compatible bonding/cement products.
  • Follow manufacturer sequence and safe handling, including HF acid safety where applicable.
  • Evaluate final contacts and polish all adjusted zirconia contacts.
Link to this topic
Clinical questions

Can I use e.max for this deep-margin onlay?

Practical direction

Yes when adequate bonded design and isolation are achievable. If margins cannot be isolated, evaluate margin exposure/elevation or change the restorative strategy rather than relying on stronger cement.

What enables the lab to answer

Photographs of margin, prep/opposing scans and proposed isolation/coverage.

Read the related reference →Link to this topic
Clinical questions

Can I make this four-unit posterior bridge?

Practical direction

Not safely from unit count alone. Assess actual connector height/area, pontic distribution, system-approved configurations, abutment support and loads.

What enables the lab to answer

Exact material system, complete prep and bite, connector space, pontic map.

Read the related reference →Link to this topic
Clinical questions

Can a thin veneer conceal a dark central incisor?

Practical direction

Not predictably without stump shade and optical trial. Consider ceramic opacity, thickness, substrate and cement together before aggressive reduction.

What enables the lab to answer

Stump, neighbouring shades, calibrated images and desired final shade.

Read the related reference →Link to this topic
Clinical questions

Can you identify my inherited implant?

Practical direction

Only from reliable manufacturer/connection/platform evidence; do not prescribe an inferred Ti-base based on appearance.

What enables the lab to answer

Placement card/operative note, component IDs, clinical image and indicated imaging.

Read the related reference →Link to this topic
Clinical questions

Can I add a tooth to a flexible partial?

Practical direction

Often less straightforward than acrylic; feasibility depends on actual polymer, clasp/design, fit and approved repair process.

What enables the lab to answer

Existing denture, polymer identification, cast/scan and extraction plan.

Read the related reference →Link to this topic
Clinical questions

Why does this lower complete denture fracture at the same site?

Practical direction

Think repetitive bending from fit/support/occlusion before simply selecting high-impact acrylic; repair, rebase and remake are different responses.

What enables the lab to answer

Denture, previous repair history, fracture photos, existing opposing teeth and bite.

Read the related reference →Link to this topic
Clinical questions

Is a hard splint the correct answer for jaw pain?

Practical direction

Do not conflate protecting restorations with chronic painful TMD management. Use targeted assessment and evidence-based management; consider appliance only for an appropriate separate indication.

What enables the lab to answer

Occlusal and wear-risk prescription when tooth protection is the purpose.

Read the related reference →Link to this topic
Clinical questions

Can I avoid a cement-retained anterior implant crown?

Practical direction

Evaluate manufacturer-supported angulated screw access and compatible Ti-base/abutment before defaulting to cement solely because the straight access is labial.

What enables the lab to answer

Exact implant platform, tissue, access axis and aesthetic scans.

Read the related reference →Link to this topic
About this reference

How a busy GDP should use it

Evidence-checked clinical and laboratory decision handbook | Research-expanded edition | 2 November 2026

This is a research-supported editorial master, not an independently peer-reviewed clinical guideline. It expands the uploaded 12-page Enhanced Clinical Edition and incorporates manufacturer specifications and professional guidance. Named figures apply only to the specific restoration, material and publication cited.

How a busy GDP should use it
Start hereGet an answer
What am I making?Section 1 fixed; Section 2 removable; Section 3 implants; Section 4 appliances
Is the restoration feasible?Compare material choice with actual preparation, connectors, space and retention
How do I seat it?Section 5 surface treatment and cementation
What does the lab need?Each entry includes a minimal prescription checklist
What has gone wrong?Section 6 problem-solving / plan-change pathways

Editorial principle: a recommendation should be confident for its defined indication. Do not substitute a generic product class for named manufacturer clearance, connection or cementation requirements.

Records & prescription

What does the laboratory need?

Open the relevant topic’s laboratory prescription or records checklist.

References, source status & publication notes

References and source status

  1. [S1] Ivoclar IPS e.max CAD product and eIFU
  2. [S2] Ivoclar IPS e.max CAD official instructions for use
  3. [S3] Original VEXA Enhanced Clinical Edition, uploaded 2 Nov 2026

    Source document; clinical synthesis where no specific external reference is stated

  4. [S4] Ivoclar IPS e.max Zirconia 2026 technical guide
  5. [S5] Ivoclar IPS e.max Zirconia product / current eIFU
  6. [S6] GC CERASMART 270 official IFU
  7. [S7] BSSPD peer-reviewed partial denture and resin-bonded bridge guidance (2026 / 2025)
  8. [S8] ITI consensus screw- versus cement-retained fixed implant restorations
  9. [S9] 2026 Global Consensus for the Rehabilitation of the Edentulous Maxilla
  10. [S10] BMJ 2023 clinical practice guideline: chronic painful TMD
  11. [S11] British Dental Journal 2021 orthodontic retention protocols
  12. [S12] Academy for Sports Dentistry 2024 position statements
  13. [S13] American College of Prosthodontists mouthguard position statement
  14. [S14] European Association for Sports Dentistry 2025 position statement
  15. [S15] NICE NG202 obstructive sleep apnoea/hypopnoea syndrome

Source classification: named product measurements are sourced from linked manufacturer material. Professional recommendations are sourced from organisations and clinical guidance listed above. Other clinical explanatory text is an editorial synthesis from the uploaded VEXA master and general restorative principles; it is not independently validated case-specific guidance.

Content coverage and publication control

Information architecture: six professional groups (Fixed, Removable, Implants, Appliances, Cementation, Clinical Questions). Users should find a restoration first, see three to five actionable options, then expand exactly the technical material they need. One authoritative entry per material; use internal links rather than duplicate paragraphs.

Not established here: a complete model-by-model implant compatibility catalogue; all proprietary zirconia grades and bridge specifications; all approved 3D-printed definitive resin systems; validated patient-specific case-planning recommendations. These require maintained data and expert oversight—not guessed specifications.

Before any public claim of clinical approval: independent restorative clinician review, GDC-registered technician review of fabrication/compatibility, date/version control, working direct IFU references for every named numerical protocol, and review of safety-critical recommendations. This master is not a clinical certification.

VEXA Clinical Reference | Research-expanded editorial master | Independent clinical sign-off required